Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Natl Compr Canc Netw ; 19(10): 1148-1155, 2021 08 03.
Artigo em Inglês | MEDLINE | ID: mdl-34343968

RESUMO

BACKGROUND: Opioid titration is necessary to achieve rapid, safe pain relief. Medication can be administered via patient-controlled analgesia (PCA) or by a healthcare provider (non-PCA). We evaluated the efficacy of intravenous PCA versus non-PCA hydromorphone titration for severe cancer pain (≥7 at rest on the 11-point numeric rating scale [NRS]). PATIENTS AND METHODS: Patients with severe cancer pain were randomized 1:1 to PCA or non-PCA titration, stratified by opioid-tolerant or opioid-naïve status. The PCA pump was set to no continuous dose, with a hydromorphone bolus dose 10% to 20% of the total previous 24-hour equianalgesic (for opioid-tolerant patients) or 0.5 mg (for opioid-naïve patients). For the non-PCA group, the initial hydromorphone bolus dose was identical to that in the PCA group, with the subsequent dose increased by 50% to 100% (for NRS unchanged or increased) or repeated at the current dose (for NRS 4-6). Hydromorphone delivery was initiated every 15 minutes (for NRS ≥4) or as needed (for NRS ≤3). The primary endpoint was time to successful titration (TST; time from first hydromorphone dose to first occurrence of NRS ≤3 in 2 consecutive 15-minute intervals). RESULTS: Among 214 patients (PCA, n=106; non-PCA, n=108), median TSTs (95% CI) were 0.50 hours (0.25-0.50) and 0.79 hours (0.50-1.42) for the PCA and non-PCA groups, respectively (hazard ratio [HR], 1.64; 95% CI, 1.23-2.17; P=.001). TSTs in opioid-tolerant patients were 0.50 hours (0.25-0.75) and 1.00 hours (0.50-2.00) for the PCA and non-PCA groups, respectively (HR, 1.92; 95% CI, 1.32-2.78; P=.003); in opioid-naive patients, TST was not significantly different for the PCA versus non-PCA groups (HR, 1.35; 95% CI, 0.88-2.04; P=.162). Pain score (median NRS; interquartile range) over 24 hours was significantly lower in the PCA group (2.80; 2.15-3.22) than in the non-PCA group (3.00; 2.47-3.53; P=.020). PCA administration produces significantly higher patient satisfaction with pain control than non-PCA administration (P<.001). CONCLUSIONS: Intravenous hydromorphone titration for severe cancer pain was achieved more effectively with PCA than with non-PCA administration.


Assuntos
Dor do Câncer , Neoplasias , Humanos , Hidromorfona/efeitos adversos , Analgésicos Opioides/efeitos adversos , Analgesia Controlada pelo Paciente , Dor do Câncer/tratamento farmacológico , Dor do Câncer/etiologia , Dor , Neoplasias/complicações , Neoplasias/tratamento farmacológico
2.
Hua Xi Kou Qiang Yi Xue Za Zhi ; 38(6): 652-656, 2020 Dec 01.
Artigo em Chinês | MEDLINE | ID: mdl-33377342

RESUMO

OBJECTIVE: To investigate the effect of three anatomical parameters (maxillary sinus width, maxillary sinus angle, and residual bone height) on the outcomes of transcrestal sinus lift with simultaneous implant placement. METHODS: A total of 60 maxillary sinuses in 42 patients were included in this study. All patients were treated with transcrestal sinus lift procedure associated with simultaneous implant placement using a composite graft material of autogenous bone and Bio-Oss. For each patient, beam computed tomography (CBCT) scans were performed preoperatively, immediately after surgery, and 6 months after surgery. The parameters were measured on the preoperative and postoperative CBCT images. The correlation of three anatomical parameters with graft resorption was analyzed using Pearson's correlation test. RESULTS: The average residual bone height was (4.46±1.55) mm. The average width of maxillary sinus was (13.86±2.71) mm. The average sinus angle was 78.09°±10.27°. A significant positive correlation was observed between maxillary sinus width and graft resorption (P<0.01). A positive association was also found between sinus angle and graft resorption (P<0.01). CONCLUSIONS: The findings show that graft bone resorption in elevated sinus has a positive correlation with the sinus width and sinus angle.


Assuntos
Reabsorção Óssea , Implantes Dentários , Levantamento do Assoalho do Seio Maxilar , Implantação Dentária Endóssea , Humanos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/cirurgia , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...